Medium Voltage

5KV XLP L824C

Recommended for low and medium voltage power of 5000 volts. Used primarily in control circuits and for airport lighting. 5KV XLP power cables can be used in conduit, duct and direct buried.  The temperature rating is 90C.

Conductor: Stranded bare copper

Insulation: Cross-linked polyethylene (XLP)

Airport Lighting: Sizes meet specs for Federal Aviation Admin per L-824-Type C.

5KV Shld EPR/PVC – 3/C

Application: 5KV/8KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated.The temperature rating is 105°C.

Conductor: Stranded bare copper

Insulation: Ethylene propylene rubber (EPR)

Shield: Copper tape shield

Jacket: PVC Jacket- 100%/ 133%

Flame Test: IEEE 383 70,000 BTU/hr flame test

Color Code: Click here

5KV Shld EPR/PVC

5KV/8KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated.

Conductor: Stranded bare copper

Insulation: Ethylene propylene rubber (EPR)- 133% 5KV and 100% 8KV

Shield: Copper tape shield

Jacket: PVC Jacket

Flame Test: IEEE 383 70,000 BTU/hr flame test

25KV Shld EPR/PVC

25KV/ 35KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated. The temperature rating is 105C.

Conductor: Stranded bare copper

Insulation: Ethylene propylene rubber (EPR)- 133% 25KV and 100% 35KV

Shield: Copper tape shield

Jacket: PVC Jacket- 100% / 133%

Flame Test: IEEE 383 70,000 BTU/hr flame test

15KV Shld EPR/PVC

15KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated. The temperature rating is 105C.

Conductor: Stranded bare copper

Insulation: Ethylene propylene rubber (EPR)- 133% level

Shield: Copper tape shield

Jacket: PVC Jacket

Flame Test: IEEE 383 70,000 BTU/hr flame test

AIA 2.4KV

Medium voltage power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried.

Conductor: Stranded bare copper

Insulation: Ethylene propylene rubber (EPR)

Armor: Aluminum interlocked armor (AIA). Special order for galvanized steel armor.

Jacket: Yellow PVC Jacket

Color Code: Click here

5KV Shld XLP/PVC

5KV/8KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated. The temperature rating is 90C

Conductor: Stranded bare copper

Insulation: Cross-linked polyethylene (XLP)

Shield: Wire shield

Jacket: PVC jacket

15KV Shld XLP/PVC

15KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. The temperature rating is 90C.

Conductor: Stranded bare copper

Insulation: Cross linked polyethylene (XLP)- 133% level

Shield: Wire Shield

Jacket: PVC Jacket

35KV SHLD EPR/PVC

35kV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (cable tray) rated. The temperature rating is 105C.

Conductor: Stranded bare copper

Insulation: Ethylene propylene rubber (EPR)- 133% level 35kV

Shield: Copper tape shield

Jacket: PVC Jacket

Flame Test: IEEE 1202 70,000 BTU/hr flame test