Instrumentation Tray Cable

VNTC Multi-Triad ST/OS 18 AWG – 16AWG

Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/TFFN

Shield: Individually shielded pairs Overall shield

Jacket: PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code: Black, white and red triads with printed numbers

VNTC Multi-Pair SP/OS 18 AWG – 16 AWG

Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated sunlight resistant for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/TFFN

Shield: Individually shielded pairs Overall shield

Jacket: Sunlight Resistant PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code:Method 9: Black and white pairs with printed numbers

VNTC Multi-Pair SP/OS – 14 AWG

Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC/THHN-2

Shield: Individually shielded pairs Overall shield

Jacket: PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code:Method 9: Black and white pairs with printed numbers

VNTC Multi-Pair Overall Shld 18 AWG – 16 AWG

Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Shield: Overall foil shield

Insulation: PVC/TFN

Jacket: PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code: Method 9: Black and white pairs with printed numbers

PLTC TRIAD ST/OS 20AWG – 16AWG

Application: Power limited tray cables (PLTC) are used in ducts, trays and conduit audio, intercom, alarm and other 300 volt instrumentation circuits. Shielding provides protection from electrostatic noise and crosstalk.

Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC

Shield: Individually shielded triads Overall shield

Jacket: PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code: Black, white and red for triads with printed numbers

PLTC Overall Shld 20 AWG – 16 AWG

Application: UL listed PLTC cable used in Class 1, Division 2 applications

Conductor: Stranded bare copper

Insulation: PVC

Jacket: PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code: Method 9: Black and white pairs with printed numbers

FREP TC Multi-Pair SP/OS 18 AWG – 16 AW

FR-EP (EPR or XLP/CPE) instrumentation tray cables (type TC) are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. FR-EP tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. Shielding provides additional protection from electrostatic noise and cross talk.

Voltage:  600 Volt

Conductor: Stranded tinned copper

Insulation: EPR or XLP

Shield: Individually shielded pairs Overall shield

Jacket: Chlorinated Polyethylene (CPE)

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code:Method 9: Black and white pairs with printed numbers

PLTC Multi-Pair SP/OS 20 AWG – 16 AWG

Power limited tray cables (PLTC) are used in ducts, trays and conduit audio, intercom, alarm and other 300 volt instrumentation circuits. Shielding provides protection from electrostatic noise and cross talk.

Rated for Class 1, Div 2 hazardous locations.

Conductor: Stranded bare copper

Insulation: PVC

Shield: Individually shielded pairs Overall shield

Jacket: PVC

Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test

Color Code:Method 9: Black and white for pairs with printed numbers