Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.
Conductor: Stranded bare copper
Insulation: PVC/TFFN
Shield: Individually shielded pairs Overall shield
Jacket: PVC
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code: Black, white and red triads with printed numbers
Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated sunlight resistant for Class 1, Div 2 hazardous locations.
Conductor: Stranded bare copper
Insulation: PVC/TFFN
Shield: Individually shielded pairs Overall shield
Jacket: Sunlight Resistant PVC
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code:Method 9: Black and white pairs with printed numbers
Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.
Conductor: Stranded bare copper
Insulation: PVC/THHN-2
Shield: Individually shielded pairs Overall shield
Jacket: PVC
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code:Method 9: Black and white pairs with printed numbers
Shielded TC-ER instrumentation cables are used in 600 volt applications for process and control signals. Shielding protects the signal from electrostatic noise and cross talk. They can be installed in ducts, trays, conduit and direct buried. Rated for Class 1, Div 2 hazardous locations.
Conductor: Stranded bare copper
Shield: Overall foil shield
Insulation: PVC/TFN
Jacket: PVC
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code: Method 9: Black and white pairs with printed numbers
Application: Power limited tray cables (PLTC) are used in ducts, trays and conduit audio, intercom, alarm and other 300 volt instrumentation circuits. Shielding provides protection from electrostatic noise and crosstalk.
Rated for Class 1, Div 2 hazardous locations.
Conductor: Stranded bare copper
Insulation: PVC
Shield: Individually shielded triads Overall shield
Jacket: PVC
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code: Black, white and red for triads with printed numbers
FR-EP (EPR or XLP/CPE) instrumentation tray cables (type TC) are used in power and control applications in the industrial and commercial markets where additional flame retardance is required. FR-EP tray cable can be direct buried or installed in cable trays. This versatile item can also be installed both indoors and outdoors. Shielding provides additional protection from electrostatic noise and cross talk.
Voltage: 600 Volt
Conductor: Stranded tinned copper
Insulation: EPR or XLP
Shield: Individually shielded pairs Overall shield
Jacket: Chlorinated Polyethylene (CPE)
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code:Method 9: Black and white pairs with printed numbers
Power limited tray cables (PLTC) are used in ducts, trays and conduit audio, intercom, alarm and other 300 volt instrumentation circuits. Shielding provides protection from electrostatic noise and cross talk.
Rated for Class 1, Div 2 hazardous locations.
Conductor: Stranded bare copper
Insulation: PVC
Shield: Individually shielded pairs Overall shield
Jacket: PVC
Flame Test: IEEE 1202/FT4 70,000 BTU/hour flame test
Color Code:Method 9: Black and white for pairs with printed numbers